We have reduced the price by 15% off the entire VICO range. Available nationally at all major electrical wholesalers!
enLighten's Vico weatherproof IP65 LED batten offers a simple T8 or T5 fluorescent batten replacement. Vico is an intelligent LED lighting solution for long lit low occupancy spaces, the Vico is available in 600mm (16W), 1200mm (30W) & 1500mm (42w) models.
The next generation of the Vico batten has been released...with improved efficacy of up to 142 Lm/W, a NEW Eco Dim switch to half power mode and an LiFeP04 battery.
The Vico is available in emergency and standard, it is ideal for corridors, fire stairs, store rooms, plant rooms and undercover car parks.
The Vico batten can be fitted with a DALI-2 compliant driver that easily connects to an existing lighting control system. DALI is not available in emergency models.
PRODUCT RANGE | |
BL06 | 600mm standard |
BL06S | 600mm with MW sensor |
BL06E | 600mm emergency |
BL06ES | 600mm emergency with MW sensor |
BL12 | 1200mm standard |
BL12S | 1200mm with MW sensor |
BL12E | 1200mm emergency |
BL12ES | 1200mm emergency with MW sensor |
BL15 | 1500mm standard |
BL15S | 1500mm with MW sensor |
BL15E | 1500mm emergency |
BL15ES | 1500mm emergency with MW sensor |
Please note that due to upgrades in our batten lights we have changed our product codes. Download the document to discover the new product code translation.
OPTICAL | |
Light source | Samsung LED |
Lumen output | 2215 - 5710 lumen |
CRI | Ra>80 |
CCT | 4000K, 5000K standard and 5700K available on request |
ELECTRICAL | |
Power consumption | 16W-42W full light output |
Operating frequency | 50/60 Hz |
Operating voltage range | 220 -240 V AC |
EMERGENCY LIGHT | |
Battery type | 6.4V 3000 mAh LiFePO4 |
Discharge time | 90 minutes |
ENVIRONMENTAL | |
IP rating | IP65 |
Impact rating | IK10 |
Weight | 600mm - 1.8kg, 1200mm - 2.9kg, 1500mm - 3.4kg |
Ambient temperature range | -25°C to +40°C(standard models) 0°C to +40°C(emergency models) |
CONTROLS - OPTIONAL | |
Microwave sensor range | 360 deg; max 8m - adjustable |
Microwave sensor operating interval | 5 sec to 10 min (default setting 30 sec) |
MOUNTING
1. Remove diffuser cover
2. Turn knobs to release and remove the gear tray
3. Feed mains cable into fitting and mount luminaire base to ceiling
4. Hang gear tray onto luminaire base using the bungy cord
5. Connect mains wiring to terminal block
6. Emergency models only: Plug green indicator cable into driver. Ensure correct polarity is maintained by keeping the raised imprint & ink mark away from driver
7. Emergency models only: connect plug from battery cable to driver & record date of commissioning on battery
8. Adjust microwave sensor settings as required - see Microwave Sensor settings section
9. Secure the gear tray and diffuse onto the base.